PLC, I/O & HMI

EK1100

Beckhoff

Beckhoff EK1100 sourcing reference. Send the complete nameplate details and required quantity for review.

Supply status

This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.

Copy the model and paste it into WhatsApp with your required quantity.

Reference details

Manufacturer / brand
Beckhoff
Model / reference
EK1100
Series / type
Confirm against nameplate
Condition
Confirm with inquiry
Quantity
Confirm with inquiry
Lead time
Confirm with inquiry

Product information

Product Overview

The EK1100 EtherCAT Coupler is the link between the EtherCAT fieldbus and the EtherCAT Terminals. It converts the passing Ethernet 100BASE-TX telegrams into E-bus signal representation, and it is the first module of every EtherCAT Terminal station.

It is one of Beckhoff’s “preferred type” products — the recommended standard coupler for new stations. One coupler plus the terminals behind it forms a complete station.

Why Buyers Specify This Model

Two RJ45 ports, so the station sits in a line

The bus interface is 2 × RJ45, letting the coupler sit inline: an incoming cable from the controller or the previous station, and an outgoing cable to the next. The distance between stations is up to 100 m over shielded Cat.5 or better Ethernet cable.

Because EtherCAT passes telegrams through rather than routing them, the propagation delay contributed by the coupler is roughly 1 µs — not a store-and-forward switch delay. That is the reason EtherCAT systems hold cycle times in the tens of microseconds with tens of nodes.

It feeds the terminals: 2000 mA on the E-bus

The EK1100 supplies 2000 mA at 5 V to the E-bus, which is what powers the terminal electronics behind it. The current drawn from the 24 V supply is 70 mA plus a quarter of the total E-bus current — Beckhoff’s published formula, not an approximation.

This matters when planning a station: add up the E-bus current of every terminal behind the coupler (each EL terminal’s data sheet gives a typical figure) and check it against the 2000 mA budget. Beyond that you insert a power refresh terminal rather than another coupler.

Power contacts and isolation

The power contacts carry up to 24 V DC / 10 A along the terminal row, so field supply can be distributed through the station instead of wired individually to each terminal. Electrical isolation between power contacts, supply voltage and Ethernet is 500 V.

Up to 65,534 EtherCAT Terminals can be addressed in a single system, so the coupler is not the practical limit on station size — the E-bus current budget and physical rail length are.

Technical Specifications (Official Beckhoff Data)

Parameter Official value
Task within EtherCAT system coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT networks
Transmission medium Ethernet/EtherCAT cable (min. Cat.5), shielded
Distance between stations max. 100 m (100BASE-TX)
Number of EtherCAT Terminals up to 65,534
Protocol EtherCAT
Propagation delay approx. 1 µs
Transmission rate 100 Mbit/s
Bus interface 2 x RJ45
Power supply 24 V DC (-15%/+20%)
Current consumption from U S 70 mA + (∑ E-bus current/4)
Current consumption from U P load
Current supply E-bus 2000 mA
Power contacts max. 24 V DC/max. 10 A
Electrical isolation 500 V (power contact/supply voltage/Ethernet)
Operating temperature -25…+60°C
Storage temperature -40…+85°C
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Relative humidity 95%, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
Protect. rating/installation pos. IP20/variable
Approvals/markings CE, CCC, UL, ATEX, IECEx, DNV, cFMus
Ex marking ATEX: / II 3G Ex ec IIC T4 Gc / IECEx: / Ex ec IIC T4 Gc / cFMus: / Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx ec IIC T4 Gc

Specifications are Beckhoff’s official product data for the EK1100. Beckhoff designates this model a “preferred type” — the recommended standard coupler.

Housing, Installation and Wiring

Data Official value
Design form compact terminal housing with signal LEDs
Material polycarbonate
Installation on 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means of double slot and key connection
Marking labeling of the BZxxxx series
Wiring solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Connection cross-section s*: 0.08…2.5 mm², / st*: 0.08…2.5 mm², / f*: 0.14…1.5 mm²
Connection cross-section AWG s*: AWG28…14, / st*: AWG28…14, / f*: AWG26…16
Stripping length 8…9 mm
Current load power contacts I max : 10 A
Dimensions (W x H x D) 44 mm x 100 mm x 68 mm

Material Compliance

The following is Beckhoff’s published material compliance data for this product, reproduced unchanged. Beckhoff notes that absence of a substance is not verified by analytical tests.

Item Official statement
REACH SVHC no
POP compliant
RoHS compliant with exemption
RoHS exemption 7c-I: Lead-containing electrical and electronic components in glass and ceramic materials, excluding dielectric ceramics in capacitors
China-RoHS www.beckhoff.com/china-rohs-io
CA Prop65 www.beckhoff.com/prop65

Official Documentation

Every figure in the table above is published by Beckhoff. We reproduce it rather than paraphrase it, so that you can check it against the manufacturer’s own documentation:

Ordering This Part

Tell us the model and, where an order code exists, the complete code — Beckhoff variants differ in ways that matter, as set out above. For discontinued models, a nameplate photograph is the fastest way to confirm exactly what you have.

  • Exact model or order code (including any suffix such as -0111 or -ES variants)
  • Quantity required
  • Whether you need the terminal alone or a complete station with coupler and power supply
  • For replacements: a photo of the existing nameplate or the old order code

We confirm availability and condition before quoting. We do not publish stock levels or lead times on this page because they change; ask and we will answer specifically for your requirement.

Frequently Asked Questions

EK1100 or EK1110 — which do I need?

The EK1100 is a coupler: it starts a station and connects EtherCAT Terminals to a 100BASE-TX network. The EK1110 is an extension: it goes at the end of a terminal segment and adds one more RJ45 port so the line can continue. Most stations need one EK1100 and, if the line carries on, one EK1110 at the end.

How many terminals can I put behind one EK1100?

The E-bus current budget is the limit that bites first: 2000 mA. Add up the typical E-bus current of each terminal (published in each data sheet) and keep the total under that. EtherCAT itself addresses up to 65,534 terminals.

How far apart can stations be?

Up to 100 m between stations over shielded Cat.5 or better Ethernet/EtherCAT cable. The propagation delay through the coupler is approximately 1 µs, and the transmission rate is 100 Mbit/s.

What 24 V supply does it need?

24 V DC (-15% / +20 %). Current consumption from the supply is 70 mA plus one quarter of the total E-bus current drawn by the terminals behind it. The power contacts carry up to 24 V DC / 10 A.

What approvals does the EK1100 carry?

CE, CCC, UL, ATEX, IECEx, DNV and cFMus, as published by Beckhoff. The Ex marking covers ATEX II 3G Ex ec IIC T4 Gc, IECEx Ex ec IIC T4 Gc, and cFMus Class I Division 2 Groups A-D / Class I Zone 2 AEx ec IIC T4 Gc.

MODEL INQUIRY

Request this
reference.

Include a nameplate photo or full specification when revisions may differ.

For photos or documents, email sales@zhenxinindustrial.com and include your model number.

Submitting does not confirm stock or create an order. We use your details to respond to this inquiry. See our Privacy Policy.