Reference packaging image. Exact product photo pending verification.
PLC, I/O & HMI
6ES7214-1BG40-0XB0
Siemens
Siemens SIMATIC S7-1200 CPU 1214C AC/DC/relay reference for exact-model industrial sourcing inquiries.
This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.
Copy the model and paste it into WhatsApp with your required quantity.
Reference details
- Manufacturer / brand
- Siemens
- Model / reference
- 6ES7214-1BG40-0XB0
- Series / type
- SIMATIC S7-1200 CPU 1214C AC/DC/relay
- Condition
- Confirm with inquiry
- Quantity
- Confirm with inquiry
- Lead time
- Confirm with inquiry
Product information
The 6ES7214-1BG40-0XB0 is a Siemens SIMATIC S7-1200 compact CPU designated CPU 1214C in the AC/DC/Relay configuration. It runs directly from 85–264 V AC mains, accepts 14 digital inputs at 24 V DC, and switches 10 relay outputs rated 2 A per contact, with 2 analog inputs at 0–10 V DC.
The AC supply and relay outputs are what distinguish this variant. Control cabinets that already have mains voltage available do not need a separate 24 V DC power supply for the CPU, and relay contacts can switch AC circuits or mixed load voltages directly — without the interface relays the transistor version would require. Where high switching frequency or pulse outputs are needed instead, the solid-state variant 6ES7214-1AG40-0XB0 is the equivalent CPU.
Technical specifications
| Manufacturer / family | Siemens · SIMATIC S7-1200 |
|---|---|
| Product type | CPU 1214C AC/DC/Relay |
| Firmware version | V4.7 |
| Engineering software | STEP 7 V20 or higher |
| Work memory | 150 kbyte integrated, not expandable |
| Load memory | 4 Mbyte integrated |
| Retentive data area, max. | 14 kbyte |
| Supply voltage | 85–264 V AC, 47–63 Hz |
| Digital inputs | 14 × 24 V DC |
| Digital outputs | 10 × relay, 2 A per contact |
| Analog inputs | 2 × 0–10 V DC |
| Analog outputs | None on board |
| CPU processing time, bit operations | 0.08 µs typical |
| Expansion per system, max. | 8 signal modules, 3 communication modules, 1 signal board |
| Communication | PROFINET with integrated switch |
| Ambient temperature | −20 … +60 °C |
| Degree of protection | IP20 |
Specifications as published in Siemens product data for this article number. Verify against the nameplate of the unit offered to you.
Lifecycle status
Siemens lists this article number as an active product with phase-out announced effective 2026-11-01. The SIMATIC S7-1200 G2 platform is identified as the successor generation, where the comparable AC-supplied CPU is the 6ES7214-1BH50-0XB0.
Typical applications
- Machine panels powered directly from mains where no separate 24 V DC supply is wanted for the controller
- Applications switching AC loads, or mixed AC and DC circuits from the same output card
- Small and medium machine control in packaging, material handling and assembly equipment
- Retrofit and replacement on existing S7-1200 AC/DC/relay installations
Application examples describe typical uses of this product type. Suitability for your own installation must be confirmed against your engineering documentation.
Related references in the S7-1200 range
- 6ES7214-1AG40-0XB0 — CPU 1214C DC/DC/DC, solid-state outputs
- 6ES7214-1BH50-0XB0 — CPU 1214C AC/DC/Relay on the newer S7-1200 G2 platform
- 6ES7215-1HG40-0XB0 — CPU 1215C DC/DC/Relay, higher memory, two analog outputs
Before you order
To confirm a specific unit, please provide the complete ordering code, hardware functional status, firmware version, a nameplate photograph, the quantity required and the delivery destination. Availability, condition, quantity, lead time and commercial terms are confirmed individually after inquiry.
Frequently asked questions
Can this CPU be connected directly to 220 V mains?
Yes. The rated supply range is 85–264 V AC at 47–63 Hz, which covers common single-phase mains voltages. The load circuit voltage and contact rating must still be checked separately.
What is the relay contact rating?
The ten integrated relay outputs are rated 2 A per contact. Confirm load type, inrush current and suppression requirements against your application.
Do relay outputs wear out?
Yes. Relay contacts have a finite mechanical and electrical life, which is why frequent or fast switching favours a solid-state output CPU instead.
Is the analog input differential or single-ended?
The two integrated analog inputs accept 0–10 V DC. Verify the wiring arrangement and grounding against the current Siemens manual for your application.
Is this CPU affected by the S7-1200 G2 transition?
Siemens has announced phase-out of this article number effective 2026-11-01, with S7-1200 G2 as the successor platform. Confirm current availability before committing to a volume requirement.
What is the price and lead time?
Confirmed individually against current availability for the specific revision and quantity.
MODEL INQUIRY
Request this
reference.