PLC, I/O & HMI

1756-L81E

Allen-Bradley

Allen-Bradley ControlLogix 5580 controller reference for exact-model industrial sourcing inquiries.

Supply status

This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.

Copy the model and paste it into WhatsApp with your required quantity.

Reference details

Manufacturer / brand
Allen-Bradley
Model / reference
1756-L81E
Series / type
ControlLogix 5580 controller
Condition
Confirm with inquiry
Quantity
Confirm with inquiry
Lead time
Confirm with inquiry

Product information

Product Overview

The 1756-L81E is an Allen-Bradley ControlLogix 5580 controller, the current-generation flagship of the 1756 platform. It ships with 3 MB of user memory, a USB 2.0 programming port, and one embedded 1 Gbps EtherNet/IP port that supports up to 100 EtherNet/IP devices directly from the controller — no separate Ethernet bridge module required. A 4-character alphanumeric display on the front panel shows module status and node identity, which speeds up commissioning and troubleshooting in crowded cabinets.

Technical Specifications (Official Rockwell Data)

Product family ControlLogix 5580 controller
User memory 3 MB
Non-volatile memory Secure Digital (SD) card
Embedded network port 1 × EtherNet/IP, 10 Mbps / 100 Mbps / 1 Gbps
EtherNet/IP devices supported up to 100
Local programming port 1 × USB 2.0 full-speed, Type B
Communication options EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink, third-party networks via 1756 bridge modules
Programming software Studio 5000 Logix Designer
Programming languages Ladder Diagram (LD), Structured Text (ST), Function Block Diagram (FBD), Sequential Function Chart (SFC)
Controller tasks 32 tasks, 1000 programs per task
Product series Series B
Lifecycle status (Rockwell) Active

Lifecycle Status & Availability

Rockwell Automation lists the 1756-L81E with lifecycle status Active — it is in current production and fully supported in the latest Studio 5000 releases. As a member of the 5580 generation, it is the recommended platform for new ControlLogix projects and for migration away from discontinued 5561/5570 controllers.

Typical Applications

  • High-speed discrete and process control where program size outgrows legacy 5561/5570 controllers
  • Plant-wide EtherNet/IP architectures: controller talks to drives, remote I/O and HMI over the embedded 1 Gbps port
  • Migration target for systems standardized on ControlLogix since the late 1990s — the 1756 chassis, I/O and power supplies are reused
  • Multi-tasking applications that separate motion, interlocks and HMI logic into independent tasks

Related & Compatible Models

The 1756-L81E is the entry model of the 5580 memory ladder: L81E (3 MB) → L83E (10 MB) → L85E (40 MB). For safety-rated applications the GuardLogix 5580 1756-L81ES provides the same platform with a dedicated safety memory partition. All 5580 controllers mount in 1756 chassis (1756-A4 … A17) powered by 1756-Px7x series power supplies.

Requesting a Quotation

Send the complete catalog number including any suffix (e.g. 1756-L81E/-B), the firmware revision printed on the label, and the required quantity. Firmware revision matters for Studio 5000 compatibility, so a nameplate photo is the most reliable way to quote. This page lists technical data only — stock, pricing and lead time are confirmed individually by quotation.

Frequently Asked Questions

What is the difference between 1756-L81E and 1756-L81?

The suffix E marks the 5580 generation with an embedded 1 Gbps EtherNet/IP port and SD-card non-volatile memory. The plain 1756-L81 belongs to the older 5570 generation without an embedded Ethernet port, which requires a separate 1756-EN2T/ENBT bridge module for EtherNet/IP.

Which Studio 5000 version do I need for a 5580 controller?

ControlLogix 5580 controllers are programmed with Studio 5000 Logix Designer version 28 or later; a full nameplate photo lets us confirm the exact firmware revision and matching software edition before you order.

Can I drop a 1756-L81E into my existing 1756 chassis?

Yes. 5580 controllers occupy one slot of any 1756 chassis and are powered from the same 1756 power supplies. Chassis, I/O modules and wiring are typically reused during a controller upgrade.

Is the SD card included?

The controller supports Secure Digital cards as the non-volatile memory option. Confirm whether an SD card is required for your application and include it in the quotation request.

Do you supply 1756-L81E worldwide?

Requests are handled individually — send the catalog number, series/firmware revision and destination so the quotation can include confirmed availability and shipping terms.

MODEL INQUIRY

Request this
reference.

Include a nameplate photo or full specification when revisions may differ.

For photos or documents, email sales@zhenxinindustrial.com and include your model number.

Submitting does not confirm stock or create an order. We use your details to respond to this inquiry. See our Privacy Policy.