INDUSTRIAL AUTOMATION
E5CC
Omron
OMRON E5CC. Reference photograph supplied by Zhenxin Industrial; the image may show the product, its nameplate or labelled packaging. Confirm the complete ordering code, revision, condition and required quantity before quotation.
This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.
Copy the model and paste it into WhatsApp with your required quantity.
Reference details
- Manufacturer / brand
- Omron
- Model / reference
- E5CC
- Series / type
- Confirm against nameplate
- Condition
- Confirm with inquiry
- Quantity
- Confirm with inquiry
- Lead time
- Confirm with inquiry
Product information
Product Overview
Omron’s 48 × 48 mm digital temperature controller: universal input, 50 ms sampling, dual 4-digit PV/SV display and a 60 mm short body. The E5CC is the workhorse of the family — relay, SSR-driving voltage or linear current control output, screw, push-in or plug-in terminals.
This page is written for buyers and maintenance engineers sourcing E5CC as a new part or a replacement. Every specification below is taken from Omron’s own published data for this model; no third-party or estimated figures are used, and where Omron publishes two different figures or two variants for the same parameter, both are shown.
Omron catalogue designation: E5CC / E5CC-B / E5CC-U digital temperature controller, 48 × 48 mm. Official catalogue code for this model: E5CC-800 series (48 × 48 mm).
Why Buyers Specify This Model
50 ms sampling and 0.3% accuracy is where the E5CC sits
±0.3% PV indication accuracy on thermocouple input with a 50 ms sampling period. In practice this is the tier where control stops being the limiting factor in an extrusion barrel, a packaging sealer or a reflow zone. The E5CC-U plug-in variant drops to ±1% PV — the price of the plug-in body — so the two are not equivalent for tight processes.
The white 15.2 mm PV display is a maintenance decision, not a cosmetic one
The change from red to a white 4-digit PV display at 15.2 mm of character height was made so the value can be read from further away and under poor panel lighting. On a machine where operators read setpoints through a window all day, that is the feature that gets noticed.
Three terminal systems for three different panels
E5CC with screw terminals, E5CC-B with Push-In Plus terminals for reduced wiring time, and E5CC-U as a plug-in that can be removed from the terminal block without unwiring. Where controller swap-out time matters — multi-zone machines with dozens of controllers — the E5CC-U is the one that matters. They are different product codes, not options.
Programless communication between controllers
E5CC supports component communications so controllers can be linked to each other and to a PLC without an explicit communications program. On a multi-zone machine this removes the serial programming work and the cable-by-cable commissioning.
Technical Specifications (Official Omron Data)
| Parameter | Official value |
|---|---|
| Size | 48 × 48 mm (E5CC screw terminal, E5CC-B Push-In Plus terminal, E5CC-U plug-in) |
| Power supply voltage | “A” in model number: 100 to 240 VAC, 50/60 Hz. “D” in model number: 24 VAC, 50/60 Hz or 24 VDC |
| Operating voltage range | 85% to 110% of rated supply voltage |
| Power consumption | Models with option selection 000: 5.2 VA max. at 100 to 240 VAC, 3.1 VA max. at 24 VAC or 1.6 W max. at 24 VDC. All other models: 6.5 VA max. at 100 to 240 VAC, 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC |
| Sensor input — thermocouple | K, J, T, E, L, U, N, R, S, B, C/W or PL II |
| Sensor input — platinum resistance thermometer | Pt100 or JPt100 |
| Sensor input — infrared temperature sensor (ES1B) | 10 to 70 °C, 60 to 120 °C, 115 to 165 °C or 140 to 260 °C |
| Sensor input — analog current | 4 to 20 mA or 0 to 20 mA |
| Sensor input — analog voltage | 1 to 5 V, 0 to 5 V, 0 to 10 V or 0 to 50 mV |
| Input impedance | Current input: 150 Ω max.; Voltage input: 1 MΩ min. |
| Indication accuracy | Thermocouple input (E5CC/E5CC-B): ±0.3% PV; Pt input: ±0.2% of PV; Analog input: ±0.2% of FS |
| Sampling period | 50 ms |
| Control method | ON/OFF control or 2-PID control with auto-tuning |
| Control output — relay | E5CC/E5CC-B: SPST-NO, 250 VAC, 3 A (resistive load); electrical life 100,000 operations; minimum applicable load 5 V, 10 mA |
| Control output — voltage (for driving SSR) | Output voltage 12 VDC ±20% (PNP); max. load current 21 mA; with short-circuit protection circuit |
| Control output — linear current | 4 to 20 mA DC / 0 to 20 mA DC; load 500 Ω max.; resolution approx. 10,000 |
| Auxiliary outputs | E5CC: 3; E5CC-B: 2; E5CC-U: 1 or 2 depending on model |
| Event inputs | E5CC: 2 or 4 depending on model |
| Body depth | 60 mm with screw terminal blocks |
| Degree of protection | E5CC/E5CC-B — Front panel: IP66 / UL Type 1; Rear case: IP20; Terminals: IP00. E5CC-U — Front panel: IP50 |
| Memory protection | Non-volatile memory (1,000,000 writes) |
| Weight | E5CC/E5CC-B: controller approx. 120 g; E5CC-U: approx. 100 g |
| Programmable with | CX-Thermo; also configurable over USB without wiring the power supply using a Communications Conversion Cable |
Model number position “A” means 100–240 VAC and “D” means 24 VAC/VDC. The control output code is a two-character pair: RX = relay, QX = voltage output for SSR drive, CX = linear current — the second character describes control output 2 (X = none). Read both characters before ordering; the code determines whether the controller can drive an SSR directly.
Lifecycle and availability
Omron’s E5CC range is a current, actively developed product line. Its datasheet (Cat. No. H177-E1-11) runs to 138 pages of specifications, model numbering and dimensions, and Omron continues to issue options and accessory codes against it.
Because the E5CC exists in three body types and a wide spread of output, supply and option combinations, the model number carries real information. Send the complete number — including the option suffix — or, for a replacement, a photograph of the controller label. We will confirm it against Omron’s official lineup rather than supply a near-equivalent.
Availability, condition of supply and lead time are quoted per enquiry because they depend on quantity and on where the goods are held. We do not publish stock or lead time as fixed figures on this page. Tell us the quantity and the date you need it and we will answer with a firm position rather than a promise.
Official Documentation
The specifications on this page are taken from Omron’s own documents. You can download the source document directly:
- E5[]C/E5[]C-T Digital Temperature Controller Datasheet (Cat. No. H177-E1-11) — https://files.omron.eu/downloads/latest/datasheet/en/h177_e5_c_e5_c-t_digital_temperature_controller_datasheet_en.pdf
Full technical detail — wiring diagrams, derating curves, installation requirements and the complete ordering tables — is in that document. If you need a specific figure we do not show here, ask and we will point you to the exact page rather than paraphrase it.
Ordering This Part
Send us the full catalogue number E5CC-800 series (48 × 48 mm) (and the model number E5CC you are replacing), the quantity, your delivery address and the date you need the goods. If it is a replacement, attach a photograph of the existing unit’s nameplate — it removes any doubt about the revision, the output type or the supply voltage, which are the three things that most often cause a wrong part to be shipped.
We do not publish stock, condition or lead time as fixed figures here, because they change: they are quoted per enquiry against the quantity and date you actually need. If a machine is down, say so and give us the required window — that is the information that determines how we source it.
Frequently Asked Questions
Which E5CC body type do I need?
E5CC = screw terminal blocks (with cover), E5CC-B = Push-In Plus terminal blocks, E5CC-U = plug-in model removable from the terminal block. The body dimensions and panel cutout are the same 48 × 48 mm; what changes is how the wires land and how fast the controller can be swapped.
Rx, Qx or Cx — which control output?
RX is a relay output, for directly switching a heater contactor or a small load. QX is a voltage output for driving an SSR. CX is a linear current output (4–20 mA / 0–20 mA), for driving a power controller or a valve positioner. Choosing wrongly means the controller cannot drive what is on the panel.
24 VDC or 100–240 VAC supply?
Position “A” is 100 to 240 VAC and “D” is 24 VAC/24 VDC. The DC version is the usual choice where the panel is already 24 V and the machine must not be live when the supply is isolated.
Does it need a separate power supply for configuration?
No — with a Communications Conversion Cable the controller can be set up from a computer over USB without wiring the power supply. On a multi-controller panel that turns a day of wiring and configuration into an afternoon.
MODEL INQUIRY
Request this
reference.
Include a nameplate photo or full specification when revisions may differ.