PLC, I/O & HMI

EL2008

Beckhoff

Beckhoff 8-channel EtherCAT digital output terminal reference for exact-model industrial sourcing inquiries.

Supply status

This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.

Copy the model and paste it into WhatsApp with your required quantity.

Reference details

Manufacturer / brand
Beckhoff
Model / reference
EL2008
Series / type
8-channel EtherCAT digital output terminal
Condition
Confirm with inquiry
Quantity
Confirm with inquiry
Lead time
Confirm with inquiry

Product information

Product Overview

The EL2008 is the standard 8-channel 24 V DC digital output terminal: 0.5 A per channel, short-circuit proof, reverse polarity protected, in a 12 mm housing. It is the default choice for a machine’s general-purpose output bank.

It consumes typically 110 mA from the E-bus; the power contacts carry 15 mA plus load.

Why Buyers Specify This Model

Eight channels is the practical default

Most machines have between four and sixteen discrete outputs of the same type — valve solenoids, indicator lamps, small contactors, enable signals. Eight per terminal hits that range without leaving half a module unused, and the 12 mm housing keeps the rail short.

Beckhoff’s 0.5 A rating with short-circuit proofing and reverse polarity protection covers the majority of those loads. Note the switching-off energy limit of < 150 mJ per channel for inductive loads.

The ES variant matters more than it looks

Beckhoff lists the ES2008 as the same terminal with a pluggable wiring level. On a machine that will be serviced over many years, a pluggable level means a failed terminal can be exchanged without disturbing the field wiring.

That is worth deciding at design time rather than after the first failure. Both codes are listed in the ordering information for this product and we can quote either.

Identical behaviour to the EL2004 and EL2809

The switching times and protections are the same across Beckhoff’s 0.5 A output family: typical 60 µs on, 300 µs off, short-circuit current below 2 A, reverse polarity protection, 150 mJ switching-off energy limit. What changes between EL2004 / EL2008 / EL2809 is the number of channels, not the electrical behaviour.

That is convenient for spares and for panel builders: one behaviour to design around, three channel counts to choose from.

Technical Specifications (Official Beckhoff Data)

Parameter Official value
Connection technology 1-wire
Number of outputs 8
Nominal voltage 24 V DC (-15%/+20%)
Load type resistive, inductive, lamp load
Distributed clocks –
Max. output current 0.5 A (short-circuit proof) per channel
Short-circuit current typ. < 2 A
Reverse polarity protection yes
Switching-off energy < 150 mJ/channel
Switching times typ. T ON : 60 µs, typ. T OFF : 300 µs
Current consumption E-bus typ. 110 mA
Current consumption power contacts typ. 15 mA + load
Bit width in the process image 8 outputs
Configuration no address or configuration setting
Electrical isolation 500 V (E-bus/field potential)
Weight approx. 55 g
Operating temperature -25…+60°C
Storage temperature -40…+85°C
Relative humidity 95%, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos. IP20/see documentation
Pluggable wiring level for all ESxxxx terminals
Approvals/markings CE, CCC, UL, ATEX, IECEx, DNV, cFMus
Ex marking ATEX: / II 3G Ex ec IIC T4 Gc / IECEx: / Ex ec IIC T4 Gc / cFMus: / Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx ec IIC T4 Gc

Specifications are Beckhoff’s official product data for the EL2008. The ES2008 variant is identical but with a pluggable wiring level.

Housing, Installation and Wiring

Data Official value
Design form compact terminal housing with signal LEDs
Material polycarbonate
Installation on 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means of double slot and key connection
Marking labeling of the BZxxxx series
Wiring solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Connection cross-section s*: 0.08…2.5 mm², / st*: 0.08…2.5 mm², / f*: 0.14…1.5 mm²
Connection cross-section AWG s*: AWG28…14, / st*: AWG28…14, / f*: AWG26…16
Stripping length 8…9 mm
Current load power contacts I max : 10 A
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm

Ordering Information and Variants

Beckhoff’s own ordering information for this product:

Order code Official description
EL2008 EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
ES2008 EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, pluggable wiring level

Material Compliance

The following is Beckhoff’s published material compliance data for this product, reproduced unchanged. Beckhoff notes that absence of a substance is not verified by analytical tests.

Item Official statement
REACH SVHC no
POP compliant
RoHS compliant with exemption
RoHS exemption 7c-I: Lead-containing electrical and electronic components in glass and ceramic materials, excluding dielectric ceramics in capacitors
China-RoHS www.beckhoff.com/china-rohs-io
CA Prop65 www.beckhoff.com/prop65

Official Documentation

Every figure in the table above is published by Beckhoff. We reproduce it rather than paraphrase it, so that you can check it against the manufacturer’s own documentation:

Ordering This Part

Tell us the model and, where an order code exists, the complete code — Beckhoff variants differ in ways that matter, as set out above. For discontinued models, a nameplate photograph is the fastest way to confirm exactly what you have.

  • Exact model or order code (including any suffix such as -0111 or -ES variants)
  • Quantity required
  • Whether you need the terminal alone or a complete station with coupler and power supply
  • For replacements: a photo of the existing nameplate or the old order code

We confirm availability and condition before quoting. We do not publish stock levels or lead times on this page because they change; ask and we will answer specifically for your requirement.

Frequently Asked Questions

How does the EL2008 differ from the EL2004?

Channel count only — 8 versus 4 — with the same 0.5 A rating, the same short-circuit and reverse polarity protection and the same switching times. Both are 12 mm wide.

Should I order the EL2008 or the ES2008?

The ES2008 has a pluggable wiring level, so a terminal can be replaced without touching the field wiring. On equipment that will be serviced for years, that is usually worth the difference. We can quote both.

What is the maximum load per channel?

0.5 A, short-circuit proof, for resistive, inductive and lamp loads, with a switching-off energy limit of less than 150 mJ per channel. For higher currents, use a relay output terminal or an interposing relay.

How much E-bus current does it need?

Typically 110 mA. The power contacts draw typically 15 mA plus the load current.

What approvals are listed?

CE, CCC, UL, ATEX, IECEx, DNV and cFMus, as published by Beckhoff, with the ATEX / IECEx Ex ec IIC T4 Gc marking. Protection rating IP20.

MODEL INQUIRY

Request this
reference.

Include a nameplate photo or full specification when revisions may differ.