Reference packaging image. Exact product photo pending verification.
Electronic Components
EL6001
Beckhoff
Beckhoff EL6001 sourcing reference. Send the complete nameplate details and required quantity for review.
This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.
Copy the model and paste it into WhatsApp with your required quantity.
Reference details
- Manufacturer / brand
- Beckhoff
- Model / reference
- EL6001
- Series / type
- Confirm against nameplate
- Condition
- Confirm with inquiry
- Quantity
- Confirm with inquiry
- Lead time
- Confirm with inquiry
Product information
Product Overview
The EL6001 adds an RS232 serial interface to an EtherCAT system, operating in conformity with the CCITT V.28 / DIN 66 259-1 standards. It is a full duplex interface with two data channels, TxD and RxD, at transmission rates from 2400 to 115,200 baud.
It is how a modern controller talks to older equipment: a barcode scanner, a label printer, a weighing terminal, a laboratory instrument, a legacy controller with a serial port and no network.
Why Buyers Specify This Model
RS232 where a network will not fit the job
Some devices simply do not have an Ethernet port and never will: a weighing indicator that is twenty years old and still accurate, a printer that works, a scanner with a fixed RS232 output. Replacing them is often more expensive and riskier than talking to them.
The EL6001 gives the controller a serial port as a normal EtherCAT terminal. The data is moved over the fieldbus and the application reads and writes it like any other process value, so the serial device becomes one more node in the machine’s architecture.
RS232 means short cable, and that matters
RS232 is a point-to-point standard with limited drive capability. The EL6001’s default configuration is 9600 baud, 8 data bits, no parity and one stop bit, adjustable up to 115,200 baud. Being point-to-point, it cannot be multidropped the way RS485 can.
If the device is more than a few metres away, or if several devices must share one link, RS232 is the wrong electrical interface regardless of the terminal. Beckhoff’s EL60xx range includes RS422 and RS485 variants for those cases; tell us the device and cable run and we will identify the right one.
Framing and protocol stay in the application
The terminal moves bytes; it does not interpret them. Framing, checksums, request/response sequencing and timeouts are implemented in the TwinCAT application, typically using the serial communication function blocks.
That is worth knowing at specification time: adding a serial device is a small software project, not a plug-and-play connection. Budget for the integration, and confirm that the device’s protocol is documented and available.
Technical Specifications (Official Beckhoff Data)
| Parameter | Official value |
|---|---|
| Connection technology | terminal contact |
| Data transfer channels | 2 (1/1), TxD and RxD, full duplex |
| Transmission rate | 2400…115,200 baud; default: 9600 baud, 8 data bits, no parity and one stop bit |
| Interfaces | 1 x RS232 |
| Bit distortion | < 3% |
| Cable impedance | – |
| Cable length | max. 15 m |
| Providing external supply | – |
| Power supply | via the E-bus |
| Distributed clocks | – |
| Electrical isolation | 500 V (E-bus/signal voltage) |
| Data buffer | 864 bytes receive buffer, 128 bytes transmit buffer |
| Configuration | no address setting, configuration via the controller |
| Current consumption power contacts | – |
| Current consumption E-bus | typ. 120 mA |
| Weight | approx. 55 g |
| Operating temperature | -25…+60°C |
| Storage temperature | -40…+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/variable |
| Pluggable wiring level | for all ESxxxx terminals |
| Approvals/markings | CE, CCC, UL, ATEX, IECEx, DNV, cFMus |
| Ex marking | ATEX: / II 3G Ex ec IIC T4 Gc / IECEx: / Ex ec IIC T4 Gc / cFMus: / Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx ec IIC T4 Gc |
Specifications are Beckhoff’s official product data for the EL6001. The connection technology is terminal contact.
Housing, Installation and Wiring
| Data | Official value |
|---|---|
| Design form | compact terminal housing with signal LEDs |
| Material | polycarbonate |
| Installation | on 35 mm DIN rail, conforming to EN 60715 with lock |
| Side by side mounting by means of | double slot and key connection |
| Marking | labeling of the BZxxxx series |
| Wiring | solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver |
| Connection cross-section | s*: 0.08…2.5 mm², / st*: 0.08…2.5 mm², / f*: 0.14…1.5 mm² |
| Connection cross-section AWG | s*: AWG28…14, / st*: AWG28…14, / f*: AWG26…16 |
| Stripping length | 8…9 mm |
| Current load power contacts | I max : 10 A |
| Dimensions (W x H x D) | 12 mm x 100 mm x 68 mm |
Ordering Information and Variants
Beckhoff’s own ordering information for this product:
| Order code | Official description |
|---|---|
| EL6001 | EtherCAT Terminal, 1-channel communication interface, serial, RS232 |
| ES6001 | EtherCAT Terminal, 1-channel communication interface, serial, RS232, pluggable wiring level |
Material Compliance
The following is Beckhoff’s published material compliance data for this product, reproduced unchanged. Beckhoff notes that absence of a substance is not verified by analytical tests.
| Item | Official statement |
|---|---|
| REACH SVHC | no |
| POP | compliant |
| RoHS | compliant with exemption |
| RoHS exemption | 7c-I: Lead-containing electrical and electronic components in glass and ceramic materials, excluding dielectric ceramics in capacitors |
| China-RoHS | www.beckhoff.com/china-rohs-io |
| CA Prop65 | www.beckhoff.com/prop65 |
Official Documentation
Every figure in the table above is published by Beckhoff. We reproduce it rather than paraphrase it, so that you can check it against the manufacturer’s own documentation:
- Beckhoff official product page — EL6001 — the source of every specification on this page.
- Beckhoff official documentation for EL6001 — downloadable PDF from Beckhoff’s documentation server.
- Canonical Beckhoff documentation link for EL6001.
Ordering This Part
Tell us the model and, where an order code exists, the complete code — Beckhoff variants differ in ways that matter, as set out above. For discontinued models, a nameplate photograph is the fastest way to confirm exactly what you have.
- Exact model or order code (including any suffix such as
-0111or-ESvariants) - Quantity required
- Whether you need the terminal alone or a complete station with coupler and power supply
- For replacements: a photo of the existing nameplate or the old order code
We confirm availability and condition before quoting. We do not publish stock levels or lead times on this page because they change; ask and we will answer specifically for your requirement.
Frequently Asked Questions
What baud rates does the EL6001 support?
2400 to 115,200 baud. The default is 9600 baud, 8 data bits, no parity, one stop bit. Other baud rates within that range are configurable.
Can I connect more than one device?
No. RS232 is point-to-point. For several devices on one link you need an RS485 or RS422 terminal — Beckhoff’s EL60xx range covers those. Tell us the devices and we will identify the correct terminal.
How do I use it in the PLC program?
The terminal transfers bytes; the protocol is handled in the TwinCAT application using the serial communication function blocks. Implementing a device protocol is a small software task — plan for it rather than expecting plug-and-play.
How far can the cable run be?
RS232 is intended for short point-to-point runs. If the device is more than a few metres from the terminal, use an RS422 or RS485 interface instead, or a serial-to-Ethernet converter at the device end.
Does it need a separate power supply?
No, it is an EtherCAT Terminal and is powered from the E-bus like the other terminals in the station. Connection technology is terminal contact.
MODEL INQUIRY
Request this
reference.
Include a nameplate photo or full specification when revisions may differ.