Reference packaging image. Exact product photo pending verification.
PLC, I/O & HMI
FX5U-64MR/ES
Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-F CPU, AC supply, relay output reference for exact-model industrial sourcing inquiries.
This page identifies a sourcing reference. It does not guarantee continuous stock. Availability, condition, quantity, lead time, and commercial terms are confirmed after inquiry.
Copy the model and paste it into WhatsApp with your required quantity.
Reference details
- Manufacturer / brand
- Mitsubishi Electric
- Model / reference
- FX5U-64MR/ES
- Series / type
- MELSEC iQ-F CPU, AC supply, relay output
- Condition
- Confirm with inquiry
- Quantity
- Confirm with inquiry
- Lead time
- Confirm with inquiry
Product information
Product Overview
The FX5U-64MR/ES is a Mitsubishi Electric MELSEC iQ-F series CPU module — the FX5U standard type with 32 inputs / 32 outputs, relay outputs, powered from AC 100–240 V, and with removable screw terminal blocks (M3 screws). It is the current-generation micro PLC that replaced the long-running FX3U family, and it is in current production (official sales status: On sale), so unlike discontinued controllers this page covers both new-build supply and genuine spare demand. Its core specification is identical across the FX5U platform: a 34 ns LD instruction execution time, 64 k-step program capacity (128 k steps with CPU firmware 1.100 or later), 120 kbytes device/label memory and 5 Mbytes data memory. Ladder, ST, FBD/LD and SFC programming are all supported from GX Works3. The value proposition is what is built in rather than bolted on: Ethernet and RS-485 ports are standard (no communication module needed for HMI, programming, MODBUS RTU/TCP or socket communication), a high-speed counter handles up to 6 ch at 200 kHz plus 2 ch at 10 kHz, positioning runs up to 4 axes at 200 kHz, and both an SD memory card slot and a web-server function are on board. The screw-terminal FX5U also carries 2 channels of analog input and 1 channel of analog output built in, so sensor inputs and drive setpoints usually need no analog module at all.
Technical Specifications (Official Mitsubishi Electric Data)
| Product family | Mitsubishi Electric MELSEC iQ-F series — FX5U standard type |
|---|---|
| Model | FX5U-64MR/ES |
| Integrated I/O | 32 inputs / 32 outputs |
| Output type | Relay output |
| Power supply | 100 to 240 V AC |
| Control system | Stored-program repetitive operation |
| I/O control system | Refresh system |
| Programming language | Ladder diagram (LD), structured text (ST), function block diagram/ladder diagram (FBD/LD), sequential function chart (SFC) |
| Program capacity | 64 k steps/128 k steps (128 kbytes/256 kbytes, flash memory) |
| Command processing time (LD / MOV) | 34 ns |
| Constant scan | 0.2 to 2000 ms (can be set in 0.1 ms increments) |
| Device/label memory | 120 kbytes |
| Data memory / standard ROM | 5 Mbytes |
| SD memory card | Memory card capacity (SD/SDHC memory card: Max. 16 Gbytes) |
| Built-in Ethernet port | 1 channel (built-in as standard) |
| Built-in RS-485 port | 1 channel (built-in as standard) |
| Built-in analog I/O | 2 ch analog input + 1 ch analog output |
| Input points / connection | 32 points / Removable terminal block (M3 screws) |
| Input type | Sink/source |
| Input signal voltage | 24 V DC +20%, -15% |
| Input signal current (X0–X17) | 5.3 mA/24 V DC |
| Output points / connection | 32 points / Removable terminal block (M3 screws) |
| Output external supply | 30 V DC or less / 240 V AC or less (“250 V AC or less” if not a CE, UL, cUL compliant item) |
| Output max. load | 2 A/point |
| Output min. load | 5 V DC, 2 mA (reference values) |
| Output response time (OFF→ON) | Approx. 10 ms |
| Output circuit insulation | Mechanical insulation |
| Power consumption | 40 W |
| Power fuse | 250 V, 5 A Time-lag fuse |
| Rush current | 30 A max. 5 ms or less/100 V AC / 60 A max. 5 ms or less/200 V AC |
| Operating ambient temperature | -20 to 55℃, non-freezing |
| Storage ambient temperature | -25 to 75℃, non-freezing |
| Operating ambient humidity | 5 to 95%RH, non-condensation |
| Dielectric withstand voltage (power/ground) | 1.5 kV AC for one minute |
| Insulation resistance | 10 MΩ or higher by 500 V DC insulation resistance tester |
| Grounding | Class D grounding (grounding resistance: 100 Ω or less) |
| Operating altitude | 0 to 2000 m |
| Overvoltage category / pollution degree | II or less / 2 or less |
| External dimensions | 220 mm (W) / 193 mm mounting hole pitch |
| Mass (weight) | Approx. 1.0 kg |
| Applicable standards | UL cUL CE(EMC) CE(LVD) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV KR |
All values above are taken verbatim from Mitsubishi Electric’s official MELSEC iQ-F specification data (mitsubishielectric.com product specification pages) and the official MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC hardware manual for external dimensions and mass. No third-party or estimated figures are used. Where the official data carries a condition or footnote, the value shown is the headline figure — request the full datasheet with your enquiry for the qualified figures.
Lifecycle Status & Availability
Mitsubishi Electric lists the FX5U-64MR/ES as on sale — an active, current-production MELSEC iQ-F CPU module, not a discontinued or phase-out item. Spares, firmware updates and the GX Works3 engineering environment are all still supported by the manufacturer.
Stock on this page is real trade stock: condition, firmware revision and quantity are confirmed individually at quotation. We do not publish a fixed lead time or inventory figure, because both change weekly.
This model takes an AC 100–240 V supply, which suits cabinets where a 24 V DC bus is not available or where the PLC is retrofitted into existing AC-powered panels.
Typical Applications
- Replacement and spare supply for existing FX5U-64MR/ES installations where the exact catalogue number and revision matter
- Machine-building and OEM panel construction on the current iQ-F platform
- Loads that switch mains or high-inrush circuits, where relay outputs are preferred over semiconductors
- Panel builds that need built-in analog I/O without buying an extra analog module
- Processes needing MODBUS RTU/TCP, CC-Link IE Field Network Basic or simple CPU-to-CPU communication over the built-in ports
Related & Compatible Models
Transistor-output equivalent: FX5U-64MT/ES. Smaller relay-output model: FX5U-32MR/ES. Larger relay-output model: FX5U-80MR/ES (40/40).
Requesting a Quotation
To quote the FX5U-64MR/ES accurately, please state the exact catalogue number, the required quantity, and whether you need the module alone or with expansion modules, SD card, battery and mounting accessories. Where a machine is down, say so and attach the existing unit’s nameplate photo — that lets us confirm the firmware revision before shipping and avoid a second delivery.
We do not publish stock levels, prices or delivery times on this page: they are confirmed individually against real availability at the time of your enquiry.
Frequently Asked Questions
Relay or transistor at 64 points?
This is the relay-output version: 2 A per point, up to 8 A per common terminal across 4 points, with mechanical isolation. The FX5U-64MT/ES is the transistor version at 0.5 A per point for high-speed switching.
How much panel width does it need?
220 mm, with a 193 mm mounting hole pitch and approximately 1.0 kg mass, per the official MELSEC iQ-F hardware manual dimensions.
Will it run an existing FX3U program?
Not directly. The FX5U is a different platform; the program must be converted and re-verified in GX Works3. The I/O and communication advantages of the FX5U generally justify the conversion for new builds, but an FX3U replacement normally needs conversion work.
Does it need an expansion module for Ethernet or RS-485?
No. Both ports are standard on every FX5U CPU module.
Is it in production?
Yes — official sales status is on sale.
MODEL INQUIRY
Request this
reference.
Include a nameplate photo or full specification when revisions may differ.